Starting Point |
Measurement
height (m) |
Magnetic
field level (µT) |
Field quantity |
Frequency
(Hz) |
ICNIRP General Public
(%) |
Distance
from starting
point (m) |
|||||
-2
(Longitudinal) |
1.0
(above ground level) |
0.585 |
resultant magnetic field |
50 |
0.585 |
-1
(Longitudinal) |
1.0
(above ground level) |
0.685 |
resultant magnetic field |
50 |
0.685 |
0
(Longitudinal) |
1.0
(above ground level) |
0.636 |
resultant magnetic field |
50 |
0.636 |
1
(Longitudinal) |
1.0
(above ground level) |
0.641 |
resultant
magnetic field |
50 |
0.641 |
2
(Longitudinal) |
1.0
(above ground level) |
0.345 |
resultant
magnetic field |
50 |
0.345 |
Starting
Point |
Measurement
height (m) |
Electric
field level (V/m) |
Field
quantity |
Frequency (Hz) |
ICNIRP General Public
(%) |
Distance from starting point (m) |
|||||
-2
(Lateral) |
1.0
(above ground level) |
1086.856 |
resultant magnetic field |
50 |
21.737 |
-1
(Lateral) |
1.0
(above ground level) |
1354.141 |
resultant magnetic field |
50 |
27.083 |
0
(Lateral) |
1.0
(above ground level) |
1516.160 |
resultant magnetic field |
50 |
30.323 |
1
(Lateral) |
1.0
(above ground level) |
1584.243 |
resultant magnetic field |
50 |
31.685 |
2
(Lateral) |
1.0
(above ground level) |
1580.432 |
resultant
magnetic field |
50 |
31.609 |
Maximum magnetic and electric field values for
the investigated overhead power lines.
Starting Point |
Measurement
height (m) |
Magnetic
field level (µT) |
Field
quantity |
Frequency (Hz) |
ICNIRP General Public
(%) |
Distance
from starting
point (m) |
|||||
6 |
0.5
(above ground level) |
0.025 |
resultant magnetic field |
50 |
0.025 |
Kitchen
(Indoors) |
1.0
(above ground level) |
0.022 |
resultant magnetic field |
50 |
0.022 |
1.5
(above ground level) |
0.014 |
resultant magnetic field |
50 |
0.014 |
|
- |
0.020 |
three-point average exposure level |
50 |
0.020 |
|
Starting
Point |
Measurement
height (m) |
Electric
field level (V/m) |
Field
quantity |
Frequency (Hz) |
ICNIRP General Public
(%) |
Distance
from starting
point (m) |
|||||
1
(Outdoors) |
1.0
(above ground level) |
633.512 |
resultant
magnetic field |
50 |
12.670 |
Maximum magnetic and electric
field values at the point of interest (house at Nicokleia).
From the measurements performed it can be concluded that the:
·
Magnetic and electric field measurements performed at the position of interest were below
the recommended General Public reference levels of the National Exposure Limits provided
in 1999/519/EC