Miscellaneous - Arxiepiskopou Makarou C Street, Souni

The EMF measurements were performed for the residence Arxiepiskopou Makariou C' in Souni on the 18th May 2012 at 4:30 p.m.

Residence Sitting room Residence bedroom 2


Limiting exposure values have been provided by the ICNIRP recommendations and are guidelines to many countries and organisations. The exposure limits at 50 Hz are tabulated in the following table according to the limits given by ICNIRP.


Reference levels for Occupational exposure ICNIRP

Frequency

Electric Field Strength, E (V/m)

Magnetic Field Strength, H (A/m)

Magnetic Flux Density, B (µT)

50 Hz

10000

400

500

Reference levels for General Public exposure ICNIRP

Frequency

Electric Field Strength, E (V/m)

Magnetic Field Strength, H (A/m)

Magnetic Flux Density, B (µT)

50 Hz

5000

80

100

Table 1: ICNIRP exposure limits for Occupational and General public exposure

The highest magnetic eld measurement was observed inside the sitting room, at the height of 1m. The measured value at this point was 0.385µT and the percentage of 0.385% as compared to the ICNIRP General Public Standard.

A detailed description of the maximum measured magnetic fields inside is shown in the following table.

Inside Field Measurements

Distance from Side /m

Maximum Magnetic Field at Z Height /m - Percentage of ICNIRP General Public Standard /%

0.3m

ICNIRP %

1m

ICNIRP %

1.75m

ICNIRP %

Inside the kitchen

Measurement Point

--

--

0.083

0.083

--

--

Inside the sitting room

Measurement Point

--

--

0.355

0.385

--

--

Inside the toilet room 1

Measurement Point

--

--

0.141

0.141

--

-- 

Inside toilet room 2

Measurement Point

--

--

0.146

0.146

--

--

Outside area

Measurement Point

--

--

0.010

0.010 

--

--

Inside the bedroom 1

Measurement Point

--

--

0.174

0.174

--

--

Inside the bedroom 2

Measurement Point

--

--

0.197

0.197

--

--

Inside the bedroom 3

Measurement Point

--

--

0.153

0.153

--

--

Inside the bathroom

Measurement Point

--

--

0.184

0.184

--

--

Table 2: Maximum magnetic field measurements

The highest electric field measurement was observed inside the sitting room, at the height of 1m. The measured value at this point was 0.637V/m and a percentage of 0.0127% as compared to the ICNIRP General Public Standard.

A detailed description of the maximum measured electric fields is shown in the following table.

Inside Field Measurements

Distance from Side /m

Maximum Electric Field at Z Height /m - Percentage of ICNIRP General Public Standard /%

0.3m

ICNIRP %

1m

ICNIRP %

1.75m

ICNIRP %

Inside the sitting room

Measurement Point

--

--

0.637

0.012

--

--

Table 3: Maximum electric field measurements