Miscellaneous - 17 K. Palama Street, Larnaca

Magnetic field measurements were performed for the residence in location 12 Kosti Palama street in Larnaca. The measurements were performed on the 14th of April 2011 at 09:30 am.

Sitting Room – 2nd Floor Maximum magnetic field measurement located in the inside area – Bedroom No. 3 (1st Floor)

Limiting exposure values have been provided by the ICNIRP recommendations and are guidelines to many countries and organizations. The exposure limits at 50 Hz are tabulated in the following table according to the limits given by ICNIRP.

Reference levels for Occupational exposure ICNIRP

Frequency

Electric Field Strength, E (V/m)

Magnetic Field Strength, H (A/m)

Magnetic Flux Density, B (µT)

50 Hz

10000

400

500

Reference levels for General Public exposure ICNIRP

Frequency

Electric Field Strength, E (V/m)

Magnetic Field Strength, H (A/m)

Magnetic Flux Density, B (µT)

50 Hz

5000

80

100

Table 1: ICNIRP Exposure limits for Occupational and General Public exposure

The maximum obtained values are represented below and compared to the ICNIRP limits. The highest magnetic field inside was observed in the Bedroom No. 3 (1st Floor), with a value 0.19 μT and a percentage of 0.19 % as compared to the ICNIRP General Public standard.

Magnetic Field Measurements

Measurement point /m

Maximum Magnetic Field at Z Height /m - Percentage of ICNIRP General Public Standard /%

0.3m

ICNIRP %

1m

ICNIRP %

1.75m

ICNIRP %

Measurements inside the residence - Living room (1st floor)

Measurement point A

--

--

0.08

0.08%

--

--

Measurements inside the residence - Bedroom 1 (1st floor)

Measurement point B

--

--

0.09

0.09%

--

--

Measurements inside the residence - Bedroom 3 (1st floor)

Measurement point C

--

-- 

0.19

0.19%

--

--

Measurements inside the residence - Bedroom 2 (1st floor)

Measurement point D

--

--

0.13

0.13%

--

--

Measurements inside the residence - Kitchen (1st floor)

Measurement point E

--

--

0.11

0.11%

--

--

Measurements inside the residence - Sitting room (2nd floor)

Measurement point F

--

--

0.14

0.14%

--

--

Measurements inside the residence - bedroom 4 (2nd floor)

Measurement point G

--

--

0.06

0.06%

--

--

Measurements inside the residence - Bedroom 5 (2nd floor)

Measurement point H

--

--

0.12

0.12%

--

 --

Table 2: Magnetic Field Measurements inside area